<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article" dtd-version="1.2" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">IJCEPC</journal-id>
<journal-title-group><journal-title>International Journal of Chemical Engineering &amp; Process Control</journal-title></journal-title-group>
<publisher><publisher-name>Thomson &amp; Ryberg Publications</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.62715/ijcepc.2026.v1.i1.pp21-26</article-id>
<article-id pub-id-type="publisher-id">0ac6922b95</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Methodology Article</subject></subj-group></article-categories>
<title-group><article-title>Debottlenecking a Wastewater Neutralisation Unit at a Specialty Chemicals Plant: A Proposed Stepwise Procedure</article-title></title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Sivakumar</surname><given-names>Oliver</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1">*</xref></contrib>
<contrib contrib-type="author"><name><surname>Lim</surname><given-names>Themba</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Forde</surname><given-names>Nokuthula</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib>
<aff id="aff1"><label>1</label>Department of Engineering, Han River Graduate Institute of Engineering, Italy</aff>
<aff id="aff2"><label>2</label>Department of Engineering, Anatolian Center for Engineering, Tanzania</aff>
<aff id="aff3"><label>3</label>Department of Engineering, Nile Delta Graduate Institute of Engineering, Jordan</aff>
</contrib-group>
<author-notes><corresp id="cor1">* Correspondence: <email>oliver.sivakumar@han.edu</email></corresp></author-notes>
<pub-date pub-type="epub" iso-8601-date="2026-07-09"><day>09</day><month>07</month><year>2026</year></pub-date>
<volume>1</volume>
<issue>1</issue>
<fpage>21</fpage>
<lpage>26</lpage>
<history>
<date date-type="received" iso-8601-date="2026-03-21"><day>21</day><month>03</month><year>2026</year></date>
<date date-type="accepted" iso-8601-date="2026-05-06"><day>06</day><month>05</month><year>2026</year></date>
</history>
<permissions><copyright-statement>© 2026 The Author(s)</copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><license-p>This is an open access article distributed under the Creative Commons Attribution 4.0 International License (CC BY 4.0).</license-p></license></permissions>
<self-uri xlink:href="https://trpub.org/article.php?id=0ac6922b95"/>
<abstract><p>At a multiproduct specialty chemicals site the wastewater neutralisation unit is rarely designed for the load it eventually receives. Products are added, campaigns overlap, and a unit that once coped begins to limit production because effluent outside the permitted pH range cannot be discharged. The instinctive remedy is a larger tank. This article proposes a procedure for finding out first what is limiting the unit, since capacity in a neutralisation system may be set by hydraulics, by reagent delivery, by mixing and dead time, by the rangeability demanded by a steep titration curve, or by the control scheme, and the remedies differ greatly in cost. The procedure borrows the logic of the theory of constraints and applies it in five phases: establishing the duty from titration curves and flow records, locating the active constraint by a set of diagnostic checks, exploiting the existing equipment, modifying it under management of change, and confirming the gain before looking for the next constraint. The diagnostic checks and the low-cost remedies associated with each type of constraint are tabulated. The procedure is assembled from textbooks and published work on pH control and wastewater treatment. It is offered as a proposal, has not been applied to a plant in this article, and its limits are stated.</p></abstract>
<kwd-group kwd-group-type="author">
<kwd>pH neutralisation</kwd>
<kwd>Debottlenecking</kwd>
<kwd>Industrial wastewater</kwd>
<kwd>Titration curve</kwd>
<kwd>pH control</kwd>
<kwd>Theory of constraints</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1"><title>1. Introduction</title>
<p>Neutralisation is among the simplest operations in industrial wastewater treatment to describe and among the hardest to run well. Acidic or alkaline effluent is mixed with a reagent until its pH lies within the range that the discharge permit or the downstream biological plant will accept (Eckenfelder, 2000; Metcalf &amp; Eddy, 2014). In Europe such permits are issued under the Industrial Emissions Directive (European Parliament and Council, 2010), and comparable regimes exist elsewhere. Effluent that is out of range cannot leave the site. When the unit cannot keep up, production has to slow or stop.</p>
<p>Specialty chemicals plants are especially exposed. They make many products in shared equipment, each with its own washings and mother liquors, and the effluent changes in flow, acidity and buffering from one campaign to the next. A neutralisation unit sized for the original product list becomes a bottleneck as the list grows. The expensive response is to add tankage. Experience recorded in the pH control literature suggests that volume is often not the limiting factor (Shinskey, 1973; McMillan, 1994).</p>
<p>This article proposes a structured way of debottlenecking such a unit. It does not describe a project at any particular plant and reports no measurements. The procedure is put forward for use and for testing, and has not been validated here.</p>
</sec>
<sec id="sec2"><title>2. Why Neutralisation Units Become Bottlenecks</title>
<p>Three features of the process explain most capacity problems: the shape of the titration curve, the dynamics of mixing and measurement, and the variability of the load.</p>
<sec id="sec2-2"><title>2.1. The titration curve and rangeability</title>
<p>pH is a logarithmic measure, so each unit represents a tenfold change in hydrogen ion activity. For a strong acid neutralised with a strong base the titration curve is nearly vertical around neutrality: a minute excess of reagent moves the pH by several units. To bring a strongly acidic stream into a narrow band the reagent must be metered with a precision, relative to its full flow, that is orders of magnitude beyond what a single control valve can deliver. Shinskey (1973) set out this rangeability problem and the classical answers to it: neutralise in stages, with coarse adjustment first and fine adjustment later, and use valves or pumps of different sizes in sequence.</p>
<p>Real effluents are seldom pure strong acids. Weak acids and bases, carbonates, phosphates and amines buffer the solution and flatten the curve, which makes control easier but raises reagent demand. Models of pH dynamics built from chemical equilibria and from reaction invariants capture this behaviour (McAvoy et al., 1972; Gustafsson and Waller, 1983), and the strong acid equivalent of Wright and Kravaris (1991) offers a way of linearising it. At a multiproduct site the difficulty is that the buffering changes with the campaign, so that controller settings which suit one effluent oscillate or respond sluggishly with another.</p>
</sec>
<sec id="sec2-3"><title>2.2. Mixing, dead time and measurement</title>
<p>A pH loop can only correct what it has seen. The delay between adding reagent and observing its effect at the electrode includes the time to disperse the reagent through the vessel, transport delay to the electrode, and the response of the electrode itself. McMillan (1994) treats the ratio of this dead time to the vessel residence time as the central design quantity: a large, poorly agitated tank has plenty of volume and still controls badly. Short-circuiting from inlet to outlet and stagnant zones make matters worse and can be diagnosed by the tracer methods of residence time distribution analysis (Levenspiel, 1999). Agitator selection and the point of reagent addition govern blend time (Paul et al., 2004). Coated or aged electrodes add a slow, drifting lag that is easily mistaken for a process problem.</p>
</sec>
<sec id="sec2-4"><title>2.3. Reagent behaviour</title>
<p>Reagents differ in speed as well as in price. Sodium hydroxide and mineral acids react almost instantly. Lime slurry is cheaper per unit of alkalinity but must dissolve before it reacts, needs longer residence time, and with sulfate-bearing effluent forms calcium sulfate scale and sludge (Eckenfelder, 2000). A unit can therefore be limited not by its vessels but by reagent preparation, by the size of a dosing pump, or by solids handling downstream.</p>
</sec>
</sec>
<sec id="sec3"><title>3. A Constraint-Led Procedure</title>
<p>The theory of constraints holds that the output of a system is set by one limiting resource at a time, and that improvement effort spent anywhere else is wasted. Goldratt and Cox (1984) reduced this to a cycle: identify the constraint, exploit it, subordinate other decisions to it, elevate it if necessary, and then start again. The procedure proposed here applies that cycle to a neutralisation unit in five phases, shown in Figure 1. The integration of operability with design that Walsh and Perkins (1996) argued for, using effluent neutralisation as an example, is the same idea approached from the design side.</p>
<fig id="fig1"><label>Figure 1</label><caption><p>The proposed debottlenecking cycle for a neutralisation unit, repeated until the required capacity is reached</p></caption><graphic xlink:href="IJCEPC_V1I1_2026_04_Figure1.png" mimetype="image" mime-subtype="png"/></fig>
<sec id="sec3-2"><title>3.1. Establishing the duty</title>
<p>The first phase defines what the unit is being asked to do. Flow records are examined for peaks and their duration, not only for averages. Samples of the influent are taken across the campaigns that matter and titrated in the laboratory with the plant reagent, giving a family of titration curves. From these follow the range of reagent demand, the steepness of the curve at the target pH, and so the precision of reagent delivery that control within the permit band requires. The permit conditions themselves, including any averaging period, are read carefully, because a limit on an instantaneous value and a limit on a composite sample call for different designs.</p>
</sec>
<sec id="sec3-3"><title>3.2. Locating the active constraint</title>
<p>The second phase asks which element fails first as load rises. Table 1 lists the candidate constraints, the way each shows itself in operation, a diagnostic check, and the remedies that should be considered before new vessels. The checks are deliberately simple. A step test with the controller in manual gives the dead time and the process gain at the current operating point. Valve position and pump stroke records show whether reagent delivery saturates. A tracer test shows whether the working volume is the nominal volume. Comparing the on-line electrode with a freshly calibrated portable instrument separates measurement faults from process faults.</p>
<table-wrap id="tbl1"><label>Table 1</label><caption><p>Candidate constraints in a neutralisation unit, with diagnostic checks and low-cost remedies</p></caption><table frame="hsides" rules="groups"><thead><tr><th>Constraint</th><th>How it shows itself</th><th>Diagnostic check</th><th>Remedies to consider first</th></tr></thead><tbody><tr><td>Mixing and dead time</td><td>Oscillation that tuning does not cure</td><td>Step test; tracer test</td><td>Relocate injection and electrode; improve agitation</td></tr><tr><td>Measurement</td><td>Slow drift; disagreement with laboratory</td><td>Check against portable meter</td><td>Cleaning routine; redundant electrodes</td></tr><tr><td>Control scheme</td><td>Good in one campaign, poor in another</td><td>Loop performance by campaign</td><td>Gain scheduling; feedforward on flow</td></tr><tr><td>Reagent kinetics and solids</td><td>pH creeps after leaving the vessel</td><td>pH of held samples over time</td><td>Longer contact time; change of reagent</td></tr></tbody></table></table-wrap>
<table-wrap id="tbl1"><label>Table 1</label><caption><p>Candidate constraints in a neutralisation unit, with diagnostic checks and low-cost remedies</p></caption><table frame="hsides" rules="groups"><thead><tr><th>Constraint</th><th>How it shows itself</th><th>Diagnostic check</th><th>Remedies to consider first</th></tr></thead><tbody><tr><td>Hydraulic</td><td>Overflow or high level at peak flow</td><td>Flow peaks against line and pump capacity</td><td>Upstream equalisation; scheduling of discharges</td></tr><tr><td>Reagent delivery</td><td>Valve or pump at its limit; pH recovers slowly</td><td>Valve position and pump stroke records</td><td>Larger or split-range dosing; stronger reagent</td></tr><tr><td>Rangeability</td><td>Cycling between high and low pH</td><td>Titration curve slope at the target</td><td>Staged neutralisation; small trim valve</td></tr></tbody></table></table-wrap>
</sec>
<sec id="sec3-4"><title>3.3. Exploiting the existing equipment</title>
<p>Once the constraint is known, the third phase seeks capacity that needs no capital. Controller tuning is revisited with a method suited to processes dominated by dead time (Skogestad, 2003), and the gain is scheduled against pH or against campaign where the titration curve changes (Åström and Hägglund, 2006). Feedforward from influent flow removes the largest measurable disturbance (Seborg et al., 2016). Electrode cleaning and calibration intervals are set from observed drift. Production scheduling can be asked to avoid the simultaneous discharge of the two most demanding streams, which is subordination in Goldratt&#x27;s sense: the rest of the plant adapts to the constraint while it remains one.</p>
</sec>
<sec id="sec3-5"><title>3.4. Modifying under management of change</title>
<p>If exploitation is not enough, the constraint is elevated by modification. The options, roughly in order of cost, are moving the reagent injection point or the electrode, adding a small trim valve or dosing pump, improving agitation, adding an in-line mixer with a fast loop ahead of the tank, installing upstream equalisation, and adding a further stage. More elaborate nonlinear or adaptive controllers have been demonstrated on laboratory neutralisation rigs (Henson and Seborg, 1994) and may suit a site with the skills to maintain them. Every modification, including a change of reagent, passes through the site&#x27;s management of change system (CCPS, 2008) with a hazard study where warranted (IEC, 2016), since neutralisation involves corrosive reagents, heat of reaction and, with some effluents, the possibility of gas evolution.</p>
</sec>
<sec id="sec3-6"><title>3.5. Confirming the gain and repeating</title>
<p>The final phase repeats the diagnostic checks of the second under the new arrangement and at the highest load that can be arranged safely. The purpose is twofold: to confirm that the constraint addressed has moved, and to learn which element now limits the unit. A debottlenecking exercise ends when the required capacity is met with a stated margin, or when the next constraint can only be relieved by an investment that has to be justified on its own terms by the usual methods of project evaluation.</p>
</sec>
</sec>
<sec id="sec4"><title>4. Where the Procedure May Not Fit</title>
<p>The procedure assumes that the constraint lies within the neutralisation unit. If the real limit is a permit condition on salt load, a downstream clarifier or the capacity of a municipal sewer, better pH control will not help, and the first phase should bring this to light. It also assumes that the influent can be characterised by a manageable number of titration curves. Where products change weekly and effluents are mixed unpredictably, the family of curves may be too wide for any fixed design, and segregation of streams at source becomes the more promising line.</p>
<p>As a proposal, the procedure carries the further limitation that its benefit has not been measured. Its value would be shown by applying it at several sites and recording, for each, which constraint was found, what was done, what the change cost, and how much capacity was gained, set against the cost of the tankage that would otherwise have been installed. Such accounts would also show whether the list of constraints in Table 1 is complete and whether the diagnostic checks discriminate between them as cleanly in practice as they do on paper.</p>
</sec>
<sec id="sec5"><title>5. Conclusion</title>
<p>A neutralisation unit that limits production is not necessarily too small. The chemistry of the titration curve, the dynamics of mixing and measurement, and the changing nature of specialty effluents mean that the active constraint may be reagent delivery, rangeability, dead time, instrumentation or control, each with remedies far cheaper than new vessels. The five-phase cycle proposed in this article gives a way of finding that constraint and dealing with it in order of cost. It awaits application, and reports from practitioners who try it would be the proper test of its usefulness.</p>
</sec>
<sec id="sec6"><title>Conflict of interest</title>
<p>To be declared by the author(s) before publication.</p>
</sec>
<sec id="sec7"><title>Funding</title>
<p>To be declared by the author(s) before publication.</p>
</sec>
</body>
<back>
<ref-list><title>References</title>
<ref id="ref1"><label>1</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>CCPS</string-name></person-group> (<year>2008</year>). <article-title>Guidelines for the Management of Change for Process Safety</article-title>. <source>Center for Chemical Process Safety, John Wiley &amp; Sons, Hoboken, NJ</source></mixed-citation></ref>
<ref id="ref2"><label>2</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Eckenfelder, W.W.</string-name></person-group> (<year>2000</year>). <article-title>Industrial Water Pollution Control, 3rd edition</article-title>. <source>McGraw-Hill, Boston</source></mixed-citation></ref>
<ref id="ref3"><label>3</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>European Parliament and Council</string-name></person-group> (<year>2010</year>). <article-title>Directive 2010/75/EU of 24 November 2010 on industrial emissions (integrated pollution prevention and control)</article-title>. <source>Official Journal of the European Union, L 334: 17-119</source></mixed-citation></ref>
<ref id="ref4"><label>4</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Goldratt, E.M. and Cox, J.</string-name></person-group> (<year>1984</year>). <article-title>The Goal: A Process of Ongoing Improvement</article-title>. <source>North River Press, Croton-on-Hudson, NY</source></mixed-citation></ref>
<ref id="ref5"><label>5</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Gustafsson, T.K. and Waller, K.V.</string-name></person-group> (<year>1983</year>). <article-title>Dynamic modeling and reaction invariant control of pH</article-title>. <source>Chemical Engineering Science</source>, <volume>38(3)</volume>, <fpage>389-398</fpage></mixed-citation></ref>
<ref id="ref6"><label>6</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Henson, M.A. and Seborg, D.E.</string-name></person-group> (<year>1994</year>). <article-title>Adaptive nonlinear control of a pH neutralization process</article-title>. <source>IEEE Transactions on Control Systems Technology</source>, <volume>2(3)</volume>, <fpage>169-182</fpage></mixed-citation></ref>
<ref id="ref7"><label>7</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>IEC</string-name></person-group> (<year>2016</year>). <article-title>IEC 61882:2016 Hazard and operability studies (HAZOP studies) - Application guide</article-title>. <source>International Electrotechnical Commission, Geneva</source></mixed-citation></ref>
<ref id="ref8"><label>8</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Levenspiel, O.</string-name></person-group> (<year>1999</year>). <article-title>Chemical Reaction Engineering, 3rd edition</article-title>. <source>John Wiley &amp; Sons, New York</source></mixed-citation></ref>
<ref id="ref9"><label>9</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>McAvoy, T.J., Hsu, E. and Lowenthal, S.</string-name></person-group> (<year>1972</year>). <article-title>Dynamics of pH in controlled stirred tank reactor</article-title>. <source>Industrial &amp; Engineering Chemistry Process Design and Development</source>, <volume>11(1)</volume>, <fpage>68-70</fpage></mixed-citation></ref>
<ref id="ref10"><label>10</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>McMillan, G.K.</string-name></person-group> (<year>1994</year>). <article-title>pH Measurement and Control, 2nd edition</article-title>. <source>Instrument Society of America, Research Triangle Park, NC</source></mixed-citation></ref>
<ref id="ref11"><label>11</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Metcalf &amp; Eddy</string-name></person-group> (<year>2014</year>). <article-title>Wastewater Engineering: Treatment and Resource Recovery, 5th edition</article-title>. <source>McGraw-Hill Education, New York</source></mixed-citation></ref>
<ref id="ref12"><label>12</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Paul, E.L., Atiemo-Obeng, V.A. and Kresta, S.M. (eds)</string-name></person-group> (<year>2004</year>). <article-title>Handbook of Industrial Mixing: Science and Practice</article-title>. <source>John Wiley &amp; Sons, Hoboken, NJ</source></mixed-citation></ref>
<ref id="ref13"><label>13</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Seborg, D.E., Edgar, T.F., Mellichamp, D.A. and Doyle, F.J.</string-name></person-group> (<year>2016</year>). <article-title>Process Dynamics and Control, 4th edition</article-title>. <source>John Wiley &amp; Sons, Hoboken, NJ</source></mixed-citation></ref>
<ref id="ref14"><label>14</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Shinskey, F.G.</string-name></person-group> (<year>1973</year>). <article-title>pH and pIon Control in Process and Waste Streams</article-title>. <source>John Wiley &amp; Sons, New York</source></mixed-citation></ref>
<ref id="ref15"><label>15</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Skogestad, S.</string-name></person-group> (<year>2003</year>). <article-title>Simple analytic rules for model reduction and PID controller tuning</article-title>. <source>Journal of Process Control</source>, <volume>13(4)</volume>, <fpage>291-309</fpage> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/S0959-1524(02)00062-8">https://doi.org/10.1016/S0959-1524(02)00062-8</ext-link></mixed-citation></ref>
<ref id="ref16"><label>16</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Walsh, S. and Perkins, J.</string-name></person-group> (<year>1996</year>). <article-title>Operability and control in process synthesis and design</article-title>. <source>Advances in Chemical Engineering</source>, <volume>23</volume>, <fpage>301-402</fpage></mixed-citation></ref>
<ref id="ref17"><label>17</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Wright, R.A. and Kravaris, C.</string-name></person-group> (<year>1991</year>). <article-title>Nonlinear control of pH processes using the strong acid equivalent</article-title>. <source>Industrial &amp; Engineering Chemistry Research</source>, <volume>30(7)</volume>, <fpage>1561-1572</fpage></mixed-citation></ref>
<ref id="ref18"><label>18</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Åström, K.J. and Hägglund, T.</string-name></person-group> (<year>2006</year>). <article-title>Advanced PID Control</article-title>. <source>ISA - The Instrumentation, Systems, and Automation Society, Research Triangle Park, NC</source></mixed-citation></ref>
</ref-list>
</back>
</article>