<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.2 20190208//EN" "https://jats.nlm.nih.gov/publishing/1.2/JATS-journalpublishing1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="review-article" dtd-version="1.2" xml:lang="en">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">IJCC</journal-id>
<journal-title-group><journal-title>International Journal of Cytology and Cytogenetics</journal-title></journal-title-group>
<publisher><publisher-name>Thomson &amp; Ryberg Publications</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.62715/ijcc.2026.v1.i1.pp8-13</article-id>
<article-id pub-id-type="publisher-id">46c8bac4c9</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Review Article</subject></subj-group></article-categories>
<title-group><article-title>Liquid-Based Cytology Versus Conventional Smears for Thyroid Fine-Needle Aspirates in Resource-Limited Laboratories</article-title></title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><name><surname>Mokoena</surname><given-names>Freya</given-names></name><xref ref-type="aff" rid="aff1"><sup>1</sup></xref><xref ref-type="corresp" rid="cor1">*</xref></contrib>
<contrib contrib-type="author"><name><surname>Jang</surname><given-names>Michael</given-names></name><xref ref-type="aff" rid="aff2"><sup>2</sup></xref></contrib>
<contrib contrib-type="author"><name><surname>Hansen</surname><given-names>Emilio</given-names></name><xref ref-type="aff" rid="aff3"><sup>3</sup></xref></contrib>
<aff id="aff1"><label>1</label>Department of Life Sciences, Pearl River Institute of Life Sciences, Lebanon</aff>
<aff id="aff2"><label>2</label>Department of Life Sciences, Parana University Centre for Life Sciences, Belgium</aff>
<aff id="aff3"><label>3</label>Department of Life Sciences, Anatolian School of Life Sciences, Brazil</aff>
</contrib-group>
<author-notes><corresp id="cor1">* Correspondence: <email>freya.mokoena@pearl.edu</email></corresp></author-notes>
<pub-date pub-type="epub" iso-8601-date="2026-08-10"><day>10</day><month>08</month><year>2026</year></pub-date>
<volume>1</volume>
<issue>1</issue>
<fpage>8</fpage>
<lpage>13</lpage>
<history>
<date date-type="received" iso-8601-date="2026-04-27"><day>27</day><month>04</month><year>2026</year></date>
<date date-type="accepted" iso-8601-date="2026-06-21"><day>21</day><month>06</month><year>2026</year></date>
</history>
<permissions><copyright-statement>© 2026 The Author(s)</copyright-statement><copyright-year>2026</copyright-year><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by/4.0/"><license-p>This is an open access article distributed under the Creative Commons Attribution 4.0 International License (CC BY 4.0).</license-p></license></permissions>
<self-uri xlink:href="https://trpub.org/article.php?id=46c8bac4c9"/>
<abstract><p>Fine-needle aspiration is the standard first investigation of a thyroid nodule, and the slide on which the aspirate is read can be made in two ways. In a conventional smear the material is spread directly on glass at the bedside. In liquid-based cytology the needle is rinsed into a preservative and a machine or a manual method deposits a thin layer of cells. Liquid-based methods were developed for cervical screening and their transfer to the thyroid has been debated for three decades. This narrative review examines that debate from the standpoint of laboratories with limited funds, few cytopathologists and uncertain supply chains. It describes how the two preparations differ in morphology, what comparative studies report about adequacy and diagnostic accuracy within the Bethesda System, and what each requires in equipment, consumables and training. The published evidence suggests broadly comparable accuracy in experienced hands, with real differences in colloid, background and nuclear detail that demand retraining. For resource-limited laboratories the review concludes that a well-made conventional smear remains a sound default, that liquid-based preparation earns its cost mainly where smear quality is poor or ancillary testing is planned, and that low-cost manual variants deserve formal evaluation.</p></abstract>
<kwd-group kwd-group-type="author">
<kwd>Thyroid nodule</kwd>
<kwd>Fine-needle aspiration</kwd>
<kwd>Liquid-based cytology</kwd>
<kwd>Conventional smear</kwd>
<kwd>Bethesda System</kwd>
<kwd>Low-resource settings</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1"><title>1. Introduction</title>
<p>Thyroid nodules are common and most are benign. The task of fine-needle aspiration is to pick out the minority that need surgery, and it has done this well enough to become the procedure of choice in clinical guidelines (Haugen et al., 2016). An early appraisal by Gharib and Goellner (1993) established its accuracy and its effect in reducing unnecessary thyroidectomy, and reporting has since been standardized by the Bethesda System for Reporting Thyroid Cytopathology, which sorts every aspirate into one of six categories with an implied risk of malignancy and a recommended action (Cibas and Ali, 2009; Ali et al., 2023).</p>
<p>None of this works unless the slide is readable. For most of the history of the technique the slide was a direct smear, made by whoever held the needle. Liquid-based cytology offers another route: the sample goes into a vial of fixative and the laboratory prepares the slide. The method removes a notoriously variable manual step, and it adds cost and changes the picture under the microscope. Opinions on whether the exchange is worthwhile for the thyroid have differed sharply (Ljung, 2008; Fadda and Rossi, 2011).</p>
<p>The question takes a particular form where money and trained staff are scarce. Pathology services in low- and middle-income countries face shortages of personnel, equipment and reliable procurement that are well documented (Wilson et al., 2018; Adesina et al., 2013). In such laboratories aspiration cytology is valued exactly because it is cheap and quick. This review asks what the published literature implies for them when a choice between preparations has to be made.</p>
</sec>
<sec id="sec2"><title>2. Approach of This Review</title>
<p>The article is a narrative review. It draws on comparative studies of liquid-based and conventional thyroid preparations, on descriptive accounts of liquid-based morphology, on a published meta-analysis, on the Bethesda System documents and on reports concerning laboratory capacity in low-resource settings. The literature was read for what it says about three matters: how the slides differ, how the diagnoses differ, and what each method demands of a laboratory. Studies are discussed individually and no pooled figures are calculated.</p>
</sec>
<sec id="sec3"><title>3. Two Ways of Making a Slide</title>
<p>In the conventional method a drop of aspirate is expelled onto a slide and spread with a second slide. Some smears are fixed at once in alcohol for Papanicolaou staining; others are air-dried for a Romanowsky stain such as May-Grünwald-Giemsa or a rapid commercial equivalent. The two stains are complementary, the first giving crisp nuclear detail and the second showing colloid and cytoplasm to advantage. Technique recommendations from the National Cancer Institute state of the science conference treat both smear types as standard (Pitman et al., 2008). The method needs glass, fixative and stain. Its weakness is the operator: thick, bloody, crushed or slowly fixed smears are the usual reason an aspirate cannot be interpreted.</p>
<p>Liquid-based preparation moves slide making into the laboratory. Two commercial systems dominate. One collects cells on a membrane filter from a methanol-based fluid and transfers them to the slide; the other enriches the sample through a density reagent and lets the cells settle from an ethanol-based fluid. Both give a circular deposit of evenly spread, alcohol-fixed cells, read with the Papanicolaou stain, with most of the blood removed (Linder, 1998). Manual substitutes also exist, in which the rinse is fixed in a locally prepared alcohol-based medium, centrifuged and applied to the slide by pipette or cytocentrifuge. Figure 1 sets the main features of the approaches side by side, including the split-sample practice in which a smear is made first and the needle is then rinsed into a vial.</p>
<fig id="fig1"><label>Figure 1</label><caption><p>Principal features of conventional smears, liquid-based preparations and the split-sample approach for thyroid aspirates</p></caption><graphic xlink:href="IJCC_V1I1_2026_02_Figure1.png" mimetype="image" mime-subtype="png"/></fig>
</sec>
<sec id="sec4"><title>4. How the Morphology Differs</title>
<p>A cytologist trained on smears who first looks at a liquid-based thyroid slide sees a familiar lesion in an unfamiliar dress. The differences were catalogued early for the filter-based method by Michael and Hunter (2000) and for thyroid specifically by Afify et al. (2001) and Cochand-Priollet et al. (2003), and are summarized in Table 1. Colloid, the chief clue to a benign nodule, is reduced in amount and changes form: thin colloid appears as folded sheets likened to tissue paper, and dense colloid as scattered droplets. Large follicular sheets and papillary fronds break into smaller groups, so architecture, on which the distinction between a benign nodule and a follicular-patterned lesion partly rests, is harder to judge.</p>
<table-wrap id="tbl1"><label>Table 1</label><caption><p>Morphological and practical differences between conventional smears and liquid-based preparations of thyroid aspirates</p></caption><table frame="hsides" rules="groups"><thead><tr><th>Feature</th><th>Conventional smear</th><th>Liquid-based preparation</th></tr></thead><tbody><tr><td>Colloid</td><td>Abundant; thin films and thick fragments easily seen</td><td>Reduced; folded tissue-paper sheets or dense droplets (Afify et al., 2001)</td></tr><tr><td>Architecture</td><td>Large sheets, intact follicles and papillae</td><td>Smaller, tighter groups; fragmented papillae</td></tr><tr><td>Nuclear detail</td><td>Depends on fixation; air-drying artifact common</td><td>Uniformly fixed; nucleoli more evident, pseudoinclusions harder to find</td></tr><tr><td>Background</td><td>Blood, lymphocytes and cyst contents retained</td><td>Clean; lymphocytes dispersed, blood largely removed</td></tr><tr><td>Stains</td><td>Papanicolaou and Romanowsky</td><td>Papanicolaou as routine</td></tr><tr><td>Screening area</td><td>Whole slide, often several slides</td><td>One small circular deposit</td></tr><tr><td>Residual material</td><td>None unless a rinse is kept</td><td>Vial residue for cell block or molecular tests</td></tr></tbody></table></table-wrap>
<p>Nuclear features shift as well. Immediate wet fixation gives consistent chromatin and makes nucleoli more conspicuous, which can lend benign follicular cells a worrying look, while the intranuclear pseudoinclusions and pale chromatin of papillary carcinoma may be less obvious than in a good smear (Cochand-Priollet et al., 2003). The background is altered too. Lymphocytes in chronic thyroiditis are scattered and partly lost, and the watery colloid and macrophages of a cyst are thinned out. A clean background helps screening and removes information at once. These are not defects in the sense of errors. They are a different set of appearances that has to be learned, and the nuclear criteria have gained in importance since the reclassification of some encapsulated follicular-patterned tumors as non-invasive neoplasms (Nikiforov et al., 2016).</p>
</sec>
<sec id="sec5"><title>5. What Comparative Studies Report</title>
<p>The first formal comparison in the thyroid, by Biscotti et al. (1995), was cautious about letting thin-layer slides replace smears, and the retrospective comparison by Afify et al. (2001) likewise favored the conventional preparation, attributing the difference to the artifacts just described. Studies from laboratories with longer experience were more positive. Tulecke and Wang (2004) correlated thin-layer cytology of follicular lesions with histology, Malle et al. (2006) reported satisfactory use of a thin-layer technique, and a multi-year survey of the sedimentation-based system described its routine application to thyroid aspirates (Geers and Bourgain, 2011). Large institutional series have examined how the distribution of diagnostic categories changes with the preparation used (Nagarajan et al., 2015).</p>
<p>The pattern across this literature is that results improve as familiarity grows, which suggests that much of the early deficit lay with the reader and not with the slide. A meta-analysis by Chong et al. (2017) found the two approaches broadly comparable in diagnostic performance, with considerable heterogeneity among the contributing studies and differences between the commercial systems. Heterogeneity is to be expected. The studies differ in whether samples were split or taken separately, in who performed the aspiration, in whether ultrasound guidance was used, and in the reference standard. Split-sample designs in particular favor the smear, which receives the first and richest part of the aspirate.</p>
<p>Adequacy deserves separate comment, because a non-diagnostic result means a repeat procedure and, in a setting where patients travel far, often a patient lost to follow-up. The Bethesda System defines an adequate thyroid aspirate by a minimum number of well-preserved follicular cell groups (Cibas and Ali, 2017), and the same criterion applies to both preparations. Liquid-based processing rescues samples that would have been obscured by blood or ruined by air-drying, yet it cannot create cells that the needle did not collect. Where the non-diagnostic rate is high because of smearing faults, a change of preparation may help; where it is high because of sampling, it will not. A meta-analysis of the Bethesda System shows how widely category rates vary between institutions for reasons unrelated to preparation (Bongiovanni et al., 2012).</p>
</sec>
<sec id="sec6"><title>6. Costs, Skills and Supply in Resource-Limited Laboratories</title>
<p>The economics are unfavorable to automated liquid-based cytology in a small laboratory. A processor must be bought and maintained, and every case consumes a proprietary vial, filter or reagent and a coated slide. The systems were priced for cervical screening programs with high volumes. A laboratory that handles a modest number of thyroid aspirates spreads the fixed cost over few cases and is exposed to interruptions in supply, import delays and the absence of local service engineers. Analyses of pathology capacity in low-income countries stress that sustainable choices are those that do not depend on a single foreign supplier (Sayed et al., 2018).</p>
<p>Skills pull in the opposite direction. The conventional smear is cheap only if it is made well, and in many hospitals the aspirator is a surgeon, an endocrinologist or a trainee with no instruction in smearing. Ljung (2008) argued that the proper answer to bad smears is to teach people to make good ones, and that liquid-based methods treat the symptom. The argument is persuasive where a cytopathologist performs or attends the aspiration and can assess the material on site. It is less so where samples arrive from distant clinics already spread, dried and broken. For that pattern of referral a vial of fixative that tolerates transport has an obvious practical appeal.</p>
<p>Retraining is a real cost in either direction. A laboratory that converts must expect a period in which readers over-call nucleoli and under-recognize colloid, and the published accounts of pitfalls should be studied before the first case is signed out (Michael and Hunter, 2000). The Bethesda atlas now illustrates liquid-based appearances alongside smears and is the most accessible training resource (Ali and Cibas, 2018). The split-sample approach, with one direct smear and a needle rinse, lets readers compare the two pictures on the same lesion and is a reasonable way to manage the transition, at the price of extra work per case.</p>
</sec>
<sec id="sec7"><title>7. Ancillary Testing and Manual Alternatives</title>
<p>One advantage of the vial is independent of morphology. Residual fluid can be used for a cell block, for immunocytochemistry or for molecular analysis without a second puncture, and proponents regard this as the strongest argument for liquid-based collection in the thyroid (Rossi et al., 2012; Fadda and Rossi, 2011). Its weight depends on whether such tests are available and affordable locally. Where molecular testing of indeterminate nodules is not offered, the benefit is limited to the occasional immunostain, which a needle rinse collected alongside a conventional smear would serve equally well.</p>
<p>Manual liquid-based methods occupy the middle ground. They need a centrifuge and a locally mixed fixative, both within reach of most laboratories, and they give the clean background and uniform fixation of the commercial systems without the recurring consumable. Their weakness is the lack of standardization: cell loss, uneven deposition and fixative composition vary from one description to the next, and comparative evidence in the thyroid is sparse. They are the option most in need of careful evaluation, because they are the option that resource-limited laboratories can actually sustain.</p>
</sec>
<sec id="sec8"><title>8. Gaps in the Evidence</title>
<p>Most comparative studies come from well-resourced centers with experienced aspirators, ultrasound guidance and histological follow-up. Their finding of near-equivalence does not transfer automatically to a district hospital where palpation-guided aspirates are smeared by rotating staff. Studies set in such laboratories, with adequacy rate and cost per diagnostic result as outcomes, are few. So are comparisons that include a manual liquid-based arm, or that measure the effect of a short course in smear technique against the purchase of equipment. Until such work is published, recommendations for these settings rest on reasoning from general principles more than on direct evidence.</p>
</sec>
<sec id="sec9"><title>9. Conclusion</title>
<p>The literature does not show that either preparation is intrinsically more accurate for thyroid aspirates once readers are familiar with it. It does show that the two are not interchangeable without retraining, and that their costs fall in different places: on the skill of the aspirator for the smear, and on equipment and consumables for the liquid-based slide. For a resource-limited laboratory a well-made conventional smear, air-dried and alcohol-fixed, remains a defensible default, and investment in aspiration and smearing technique is likely to be repaid. Liquid-based preparation is most justified where specimens are referred from afar, where smear quality cannot be controlled or where residual material will be used. Manual variants merit systematic study.</p>
</sec>
<sec id="sec10"><title>Conflict of interest</title>
<p>To be declared by the author(s) before publication.</p>
</sec>
<sec id="sec11"><title>Funding</title>
<p>To be declared by the author(s) before publication.</p>
</sec>
</body>
<back>
<ref-list><title>References</title>
<ref id="ref1"><label>1</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Adesina, A., Chumba, D., Nelson, A.M., et al.</string-name></person-group> (<year>2013</year>). <article-title>Improvement of pathology in sub-Saharan Africa</article-title>. <source>The Lancet Oncology</source>, <volume>14(4)</volume>, <fpage>e152-e157</fpage></mixed-citation></ref>
<ref id="ref2"><label>2</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Afify, A.M., Liu, J. and Al-Khafaji, B.M.</string-name></person-group> (<year>2001</year>). <article-title>Cytologic artifacts and pitfalls of thyroid fine-needle aspiration using ThinPrep: A comparative retrospective review</article-title>. <source>Cancer</source>, <volume>93(3)</volume>, <fpage>179-186</fpage></mixed-citation></ref>
<ref id="ref3"><label>3</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Ali, S.Z. and Cibas, E.S. (eds.)</string-name></person-group> (<year>2018</year>). <article-title>The Bethesda System for Reporting Thyroid Cytopathology: Definitions, Criteria, and Explanatory Notes, 2nd ed</article-title>. <source>Springer, Cham</source></mixed-citation></ref>
<ref id="ref4"><label>4</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Ali, S.Z., Baloch, Z.W., Cochand-Priollet, B., Schmitt, F.C., Vielh, P. and VanderLaan, P.A.</string-name></person-group> (<year>2023</year>). <article-title>The 2023 Bethesda System for Reporting</article-title>. <source>Thyroid Cytopathology. Thyroid, 33(9): 1039-1044</source> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1089/thy.2023.0141">https://doi.org/10.1089/thy.2023.0141</ext-link></mixed-citation></ref>
<ref id="ref5"><label>5</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Biscotti, C.V., Hollow, J.A., Toddy, S.M. and Easley, K.A.</string-name></person-group> (<year>1995</year>). <article-title>ThinPrep versus conventional smear cytologic preparations in the analysis of thyroid fine-needle aspiration specimens</article-title>. <source>American Journal of Clinical Pathology</source>, <volume>104(2)</volume>, <fpage>150-153</fpage></mixed-citation></ref>
<ref id="ref6"><label>6</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Bongiovanni, M., Spitale, A., Faquin, W.C., Mazzucchelli, L. and Baloch, Z.W.</string-name></person-group> (<year>2012</year>). <article-title>The Bethesda System for Reporting Thyroid Cytopathology: A meta-analysis</article-title>. <source>Acta Cytologica</source>, <volume>56(4)</volume>, <fpage>333-339</fpage> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1159/000339959">https://doi.org/10.1159/000339959</ext-link></mixed-citation></ref>
<ref id="ref7"><label>7</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Chong, Y., Ji, S.-J., Kang, C.S. and Lee, E.J.</string-name></person-group> (<year>2017</year>). <article-title>Can liquid-based preparation substitute for conventional smear in thyroid fine-needle aspiration? A systematic review based on meta-analysis</article-title>. <source>Endocrine Connections</source>, <volume>6(8)</volume>, <fpage>817-829</fpage></mixed-citation></ref>
<ref id="ref8"><label>8</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Cibas, E.S. and Ali, S.Z.</string-name></person-group> (<year>2009</year>). <article-title>The Bethesda System for Reporting Thyroid Cytopathology</article-title>. <source>American Journal of Clinical Pathology</source>, <volume>132(5)</volume>, <fpage>658-665</fpage> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1309/AJCPPHLWMI3JV4LA">https://doi.org/10.1309/AJCPPHLWMI3JV4LA</ext-link></mixed-citation></ref>
<ref id="ref9"><label>9</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Cibas, E.S. and Ali, S.Z.</string-name></person-group> (<year>2017</year>). <article-title>The 2017 Bethesda System for Reporting</article-title>. <source>Thyroid Cytopathology. Thyroid, 27(11): 1341-1346</source> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1089/thy.2017.0500">https://doi.org/10.1089/thy.2017.0500</ext-link></mixed-citation></ref>
<ref id="ref10"><label>10</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Cochand-Priollet, B., Prat, J.J., Polivka, M., et al.</string-name></person-group> (<year>2003</year>). <article-title>Thyroid fine needle aspiration: The morphological features on ThinPrep slide preparations. Eighty cases with histological control</article-title>. <source>Cytopathology</source>, <volume>14(6)</volume>, <fpage>343-349</fpage></mixed-citation></ref>
<ref id="ref11"><label>11</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Fadda, G. and Rossi, E.D.</string-name></person-group> (<year>2011</year>). <article-title>Liquid-based cytology in fine-needle aspiration biopsies of the thyroid gland</article-title>. <source>Acta Cytologica</source>, <volume>55(5)</volume>, <fpage>389-400</fpage></mixed-citation></ref>
<ref id="ref12"><label>12</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Geers, C. and Bourgain, C.</string-name></person-group> (<year>2011</year>). <article-title>Liquid-based FNAC of the thyroid: A 4-year survey with SurePath</article-title>. <source>Cancer Cytopathology</source>, <volume>119(1)</volume>, <fpage>58-67</fpage></mixed-citation></ref>
<ref id="ref13"><label>13</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Gharib, H. and Goellner, J.R.</string-name></person-group> (<year>1993</year>). <article-title>Fine-needle aspiration biopsy of the thyroid: An appraisal</article-title>. <source>Annals of Internal Medicine</source>, <volume>118(4)</volume>, <fpage>282-289</fpage></mixed-citation></ref>
<ref id="ref14"><label>14</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Haugen, B.R., Alexander, E.K., Bible, K.C., et al.</string-name></person-group> (<year>2016</year>). <article-title>2015 American</article-title>. <source>Thyroid Association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer. Thyroid, 26(1): 1-133</source></mixed-citation></ref>
<ref id="ref15"><label>15</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Linder, J.</string-name></person-group> (<year>1998</year>). <article-title>Recent advances in thin-layer cytology</article-title>. <source>Diagnostic Cytopathology</source>, <volume>18(1)</volume>, <fpage>24-32</fpage></mixed-citation></ref>
<ref id="ref16"><label>16</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Ljung, B.-M.</string-name></person-group> (<year>2008</year>). <article-title>Thyroid fine-needle aspiration: Smears versus liquid-based preparations</article-title>. <source>Cancer</source>, <volume>114(3)</volume>, <fpage>144-148</fpage></mixed-citation></ref>
<ref id="ref17"><label>17</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Malle, D., Valeri, R.-M., Pazaitou-Panajiotou, K., Kiziridou, A., Vainas, I. and Destouni, C.</string-name></person-group> (<year>2006</year>). <article-title>Use of a thin-layer technique in thyroid fine needle aspiration</article-title>. <source>Acta Cytologica</source>, <volume>50(1)</volume>, <fpage>23-27</fpage></mixed-citation></ref>
<ref id="ref18"><label>18</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Michael, C.W. and Hunter, B.</string-name></person-group> (<year>2000</year>). <article-title>Interpretation of fine-needle aspirates processed by the ThinPrep technique: Cytologic artifacts and diagnostic pitfalls</article-title>. <source>Diagnostic Cytopathology</source>, <volume>23(1)</volume>, <fpage>6-13</fpage></mixed-citation></ref>
<ref id="ref19"><label>19</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Nagarajan, N., Schneider, E.B., Ali, S.Z., Zeiger, M.A. and Olson, M.T.</string-name></person-group> (<year>2015</year>). <article-title>How do liquid-based preparations of thyroid fine-needle aspiration compare with conventional smears? An analysis of 5475 specimens</article-title>. <source>Thyroid</source>, <volume>25(3)</volume>, <fpage>308-313</fpage></mixed-citation></ref>
<ref id="ref20"><label>20</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Nikiforov, Y.E., Seethala, R.R., Tallini, G., et al.</string-name></person-group> (<year>2016</year>). <article-title>Nomenclature revision for encapsulated follicular variant of papillary thyroid carcinoma: A paradigm shift to reduce overtreatment of indolent tumors</article-title>. <source>JAMA Oncology</source>, <volume>2(8)</volume>, <fpage>1023-1029</fpage> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1001/jamaoncol.2016.0386">https://doi.org/10.1001/jamaoncol.2016.0386</ext-link></mixed-citation></ref>
<ref id="ref21"><label>21</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Pitman, M.B., Abele, J., Ali, S.Z., et al.</string-name></person-group> (<year>2008</year>). <article-title>Techniques for thyroid FNA: A synopsis of the National Cancer Institute Thyroid Fine-Needle Aspiration State of the Science Conference</article-title>. <source>Diagnostic Cytopathology</source>, <volume>36(6)</volume>, <fpage>407-424</fpage></mixed-citation></ref>
<ref id="ref22"><label>22</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Rossi, E.D., Zannoni, G.F., Moncelsi, S., et al.</string-name></person-group> (<year>2012</year>). <article-title>Application of liquid-based cytology to fine-needle aspiration biopsies of the thyroid gland</article-title>. <source>Frontiers in Endocrinology</source>, <volume>3</volume>, <fpage>57</fpage></mixed-citation></ref>
<ref id="ref23"><label>23</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Sayed, S., Cherniak, W., Lawler, M., et al.</string-name></person-group> (<year>2018</year>). <article-title>Improving pathology and laboratory medicine in low-income and middle-income countries: Roadmap to solutions</article-title>. <source>The Lancet</source>, <volume>391(10133)</volume>, <fpage>1939-1952</fpage></mixed-citation></ref>
<ref id="ref24"><label>24</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Tulecke, M.A. and Wang, H.H.</string-name></person-group> (<year>2004</year>). <article-title>ThinPrep for cytologic evaluation of follicular thyroid lesions: Correlation with histologic findings</article-title>. <source>Diagnostic Cytopathology</source>, <volume>30(1)</volume>, <fpage>7-13</fpage></mixed-citation></ref>
<ref id="ref25"><label>25</label><mixed-citation publication-type="other"><person-group person-group-type="author"><string-name>Wilson, M.L., Fleming, K.A., Kuti, M.A., Looi, L.M., Lago, N. and Ru, K.</string-name></person-group> (<year>2018</year>). <article-title>Access to pathology and laboratory medicine services: A crucial gap</article-title>. <source>The Lancet</source>, <volume>391(10133)</volume>, <fpage>1927-1938</fpage> <ext-link ext-link-type="uri" xlink:href="https://doi.org/10.1016/S0140-6736(18)30458-6">https://doi.org/10.1016/S0140-6736(18)30458-6</ext-link></mixed-citation></ref>
</ref-list>
</back>
</article>